0

Out of 0 Ratings

Owner's of the Air King Ventilation Hood EXHAUST FANS gave it a score of 0 out of 5. Here's how the scores stacked up:
  • Reliability

    0 out of 5
  • Durability

    0 out of 5
  • Maintenance

    0 out of 5
  • Performance

    0 out of 5
  • Ease of Use

    0 out of 5
of 1
 
SPECIFICATIONS
EXHAUST FANS
ASLC50
50 CFM/3.0 SONES @ 0.10" WG. -HVI CERTIFIED
120 Volts, 1.4 amps, 60 hz.
Grill
White polymeric grill secured in place via screw mounting
through the light housing, dimensions - 11" x 10
1
/
2
".
Light Lens
High impact polycarbonate lens, secured in position using
integral tabs; easily removed if necessary.
Light Housing
Heavy gauge cold rolled steel c/w baked enamel finish; locks
in place on the grill via two integral tabs.
Blower Wheel
One piece polymeric wheel, 4
1
/
2
" diameter, 1" wide, with 10 fins.
Motor
Single coil plug-in, two pole motor, life time lubrication, thermally
protected. Rated 120 volts, 60 hz., 1.4 amps.
Fan Housing
23 ga. Galvanized metal housing, dimensions 7
3
/
8
" x 7
5
/
8
" x 5
7
/
8
",
double metal thickness mounting tabs.
Duct Collar
Plastic collar for 4" duct connection, comes complete with built
in non-metallic back draft damper for quiet operation.
Lighting
100 watt maximum, type A19, medium base bulb.
CUL/HVI
Canada: 110 Glidden Road
Brampton, Ontario L6T 2J3
Tel: (905) 456-2033
Fax: (905) 456-1015
U.S.: 820 Lincoln Drive
West Chester, Pennsylvania 19380-4466
Tel: (610) 692-7400 • 877-304-3785
Fax: (610) 696-8048
Updated 5-06Specifications subject to change without notice.
Unit Mounting
Rated Type IC for ceilings insulated to R-40. Designed to mount
in ceilings with at least 6" of clearance. The unit will mount
directly to the joist or using the supplied mounting bars with a
rough in opening of 7
5
/
8
" x 7
7
/
8
". The housing will mount through
drywall thickness up to
3
/
4
".
Ventilating Area
For bathrooms up to 50 sq. ft. for other rooms up to 60 sq. ft.
Single Pack Shipping Info
Box Dim: 11
3
/
4
" x 13
1
/
4
" x 9
3
/
8
"
UPC: 0-8316225411-5
Shipping Weight: 6 lbs.
CUS
PROJECT
LOCATION
CONTRACTOR
ARCHITECT
ENGINEER
SUBMITTED BY DATE
FAN MODEL
CFM
IN
RPM WATTS AMPS SONES QTY
OPTIONAL EQUIPMENT
NUMBER NUMBER W.G. & REMARKS
Acceptable for use over tub or shower when
installed in a GFCI protected branch circuit.
PERFORMANCE
HVI Sones Fan Speed Power
Static Pressure (inches of w.g.) @ .1 SP RPM Watts
0 0.05 0.1 0.125 0.15 0.2 0.25 0.3
Air Flow - CFM
55 53 50 49 47 44 39 34 3.0 2125 48
5
7
/
8"
4"
7
5
/
8"
7
3
/
8"
11"
10
1
/
2"